Ventilation with Lower Tidal Volumes as Compared with Traditional Tidal Volumes for Acute Lung Injury and the Acute Respiratory Distress Syndrome is a research paper published in New England Journal of Medicine (2000). On theSindex it has a DataRank of 1.4. It has been cited 12,831 times.
BackgroundTraditional approaches to mechanical ventilation use tidal volumes of 10 to 15 ml per kilogram of body weight and may cause stretch-induced lung injury in patients with acute lung injury and the acute respiratory distress syndrome. We therefore conducted a trial to determine whether ventilation with lower tidal volumes would improve the clinical outcomes in these patients.MethodsPatients with acute lung injury and the acute respiratory distress syndrome were enrolled in a multicenter, randomized trial. The trial compared traditional ventilation treatment, which involved an initial tidal volume of 12 ml per kilogram of predicted body weight and an airway pressure measured after a 0.5-second pause at the end of inspiration (plateau pressure) of 50 cm of water or less, with ventilation with a lower tidal volume, which involved an initial tidal volume of 6 ml per kilogram of predicted body weight and a plateau pressure of 30 cm of water or less. The primary outcomes were death before a patient was discharged home and was breathing without assistance and the number of days without ventilator use from day 1 to day 28.ResultsThe trial was stopped after the enrollment of 861 patients because mortality was lower in the group treated with lower tidal volumes than in the group treated with traditional tidal volumes (31.0 percent vs. 39.8 percent, P=0.007), and the number of days without ventilator use during the first 28 days after randomization was greater in this group (mean [+/-SD], 12+/-11 vs. 10+/-11; P=0.007). The mean tidal volumes on days 1 to 3 were 6.2+/-0.8 and 11.8+/-0.8 ml per kilogram of predicted body weight (PConclusionsIn patients with acute lung injury and the acute respiratory distress syndrome, mechanical ventilation with a lower tidal volume than is traditionally used results in decreased mortality and increases the number of days without ventilator use.
FAIR checklist signals are shown for context only and do not affect DataRank scoring.
Base Score Contribution
1.4
From this paper's citation signal
Citation Network Contribution
0
Citation network not refreshed for this result
This paper's DataRank is currently driven only by its base citation score. Citation network data was not refreshed for this result.
Learn more about DataRank methodology →DataRank blends this paper's own citation count with the influence of the papers that cite it. Here, roughly 100% comes from its base citations and 0% from the citation network.
Citers are pulled from OpenAlex sorted by cited_by_count:descand capped per paper, so when the cap binds we keep the highest-signal references and the score is reproducible across reruns.